S-Class 39
4.3.1 Database Modification Example
This section details the modification of an Operational Database
parameter. The following example increases the printing speed parameter
from 6 to 8 IPS on the ST-3210; however, using the same basic
procedure, any of the parameters can be changed regardless of the printer
model.
If on-line, press the PAUSE button to place the printer off-line.
Press and hold the F2 button until the On-Line Indicator is lit
(approximately six seconds) then release.
The printer will turn off the
On-Line Indicator and
print:
STOCK ID = 5
Press the F2 button three times (allow time for printing following
each button press), to arrive at the Print Speed parameter.
The printer will print:
PRINT SPEED = 6 IPS
PARSER MODE = AUTO
TICKET WIDTH = 189 (48 MM)
STOCK ID = 5
Press the F1 button two times (again, allow time for printing
following each button press), to arrive at the 8 IPS setting.
The printer will print:
PRINT SPEED = 8 IPS
PRINT SPEED = 7 IPS
PRINT SPEED = 6 IPS
PARSER MODE = AUTO
TICKET WIDTH = 189 (48 MM)
STOCK ID = 5
To save the changes and exit the mode, press and hold the F2 button
until the On-Line Indicator is lit (approximately six seconds) then
release.
The parameter changes can be confirmed by printing a Configuration
Ticket; see Section 3.5.1.