Datamax-oneil Performance series User Guide Manual de usuario Pagina 86

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 143
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 85
4 | Menu System
Performance Series User’s Guide 108
e. Options
The following settings may be adjusted:
Cutter - Controls the cutting action of the media.
GPIO - Controls the application of labels.
Present Sensor - Controls the “on-demand” dispensing of labels.
Rewinder - Controls the operation of the powered internal label rewinder.
Cutter
The following settings may be adjusted for printers with the cutter option installed:
Table 7: Cutter Settings
Note: *A positive value rotates the blade further.
GPIO
The following settings may be adjusted for printers with the GPIO option installed:
Table 8: GPIO Settings
Adjustments Options Ranges Default
Cutter Mode Off
Cut By Label
Cut By Job
Cut By Count
Off
Cut By Count 1
Cut Distance Adjust -100 to 100 dots 0
Cut Rotation Adjust -10 to 10* 0
Adjustments Values Ranges Default
GPIO Mode Off
Custom
Off
Slew Speed 2 - 10 IPS 8 IPS
Pulse Width 1 - 2000μs 1000μs
Vista de pagina 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 142 143

Comentarios a estos manuales