Set the Printer
RFID default settings (listed below by encoder [MODE] type) can be modified via the Control Panel:
HF RFID Default Settings (MODE = HF):
RFID POSITION = 1.1
TAG TYPE = ISO 15693
RETRY ATTEMPTS = 3
UHF RFID Default Settings (MODE = UHF):
RFID POSITION = 1.1
TAG TYPE = GEN 2
TAG DATA SIZE = 96-BIT
RETRY ATTEMPTS = 3
Change an RFID default by selecting, modifying, and saving the desired setting(s):
Step Instruction Display
1
Press MENU.


2
Using the DOWN Button, scroll to PRINTER OPTIONS and then
press ENTER.


3
Scroll to RFID and then press ENTER.


4
Scroll to the setting to be modified (for example, RETRY ATTEMPTS)
and then press ENTER.


5
Enter the desired setting, and then press ENTER. An asterisk will
appear next to the setting.


6
Press ESC; and, at the SAVE CHANGES prompt, press ENTER
to
complete the setup.


Notes: (1) If NOT INSTALLED is displayed after selecting RFID, the wrong device may be enabled;
go to the MODE setting and ensure that the correct RFID device has been selected.
(2) To restore factory defaults, select SET DEFAULTS in the RFID options menu.