Datamax O'Neil 4310e Manual del operador Pagina 63

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 62
Chapter 4 – Menu System 57
DISPLAYED ITEM ITEM DESCRIPTION
SENSOR READINGS
Displays the values (0 – 255) from the printer sensors, where:
THR TRAN RIBM 24V
103 091 009 171
PS HD RANK
003 255 050
THR = Printhead thermistor sensor;
TRAN = Gap media sensor (REFL when set to reflective);
RIBM = Ribbon sensor;
24V = 24 volt power supply sensor;
PS = Present sensor;
HD = Printhead position sensor; and,
RANK = Printhead ranking resistor.
RIBBON SENSOR
LIMITS
Displays the values from the ribbon sensor readings (see example below) for
printers equipped with the thermal transfer option, where:
RIBBON ADC LOW
111
RIBBON ADC HIGH
249
iPH REPORT Displays the IntelliSEAQ™ printhead report data, where:
VIEW Displays the data.
PRINT Prints a reference label:
iPH REPORT
TUE 12:44PM 23MAY2006
4212-HE25-060224-090
PRINTHEAD SERIAL #: 5x-00289
PRINTHEAD MODEL # 163
PRINTER SERIAL # 60430014
PRINTHEAD INCHES 11175
INSTALLATION DATE - INITIAL 02/02/2006
INSTALLATION DATE - LAST 28/ 02/2006
PRINTHEAD CLEANING
CLEAN PROCEDURES: 0
CLEAN COUNTER RESET 0
NUMBER OF INCHES - INITIAL 0
FLASH MODULE
REPORT
Displays the module report data, where:
VIEW Displays the data.
PRINT Prints a reference label:
FLASH MODULE REPORT
SUN 12:44PM 23MAY2011
Module G Mount Fail: 0
Module G Reformatted: 0
Vista de pagina 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 95 96

Comentarios a estos manuales

Sin comentarios